RGT-12SVC - Reactive power regulator 12 levels +TCR with RS485 ModBus RTU
Failed to load pickup availability
Online bank payment - after ordering you will be redirected to the payment service, payment confirmation will be sent to you by email
Cash on delivery - payment is made to the driver of the transport company according to the payment rule
By transfer - you will receive an advance invoice in your email no later than the next working day, where you will find the account number, which you enter when making the payment.
Invoice - this payment option is available to partners who have a framework agreement with us.
If you want to use the last two payment methods, please call our manager and he will give you instructions on how to get an invoice with or without VAT.
The electronic devices we supply meet high quality standards, have a 24-month warranty, and meet all EU requirements.
In the event of a complaint, there is no charge for returning the product.
12 steps + TCR Reactive power regulator with 2.9 inch graphic LCD and RS-485 (TENSE)
The reactive power regulator RGT-12SVC (TENSE) is a fully automatic device for optimal switching of compensation levels.
Digital measurement data processing ensures high accuracy in voltage, current and power factor evaluation.
The device setup is fully automatic - the controller itself recognizes the size of the connected compensation levels. These parameters can also be entered manually.
The control device switches the compensation levels on and off in such a way that the reactive power is controlled with the least possible number of switching operations. At the same time, the control device takes into account the even loading of the individual levels and primarily switches those that have been switched off for the longest time and have a low residual charge. During the control process, the compensation levels are continuously checked - disturbances and changes in values are detected, temporarily removed levels are regularly tested and, if necessary, reconnected to the control process.
Generator feed and generator compensation
Operating times, discharge and settling can be adjusted
Remote communication via RS485 (RS485 ModBus RTU)
Single-phase, two-phase and three-phase capacitor and shunt reactor can be connected
Harmonic voltages and currents can be monitored up to the 31st harmonic
Total energy (import/export) can be monitored
-
THD-V and THD-I values for each phase can be monitored
Creating a power analysis (20 samples 9999 min.) - for capacitor selection