Three-phase network parameter analyzer for current, voltage, frequency, power, and energy RS485
Failed to load pickup availability
Online bank payment - after ordering you will be redirected to the payment service, payment confirmation will be sent to you by email
Cash on delivery - payment is made to the driver of the transport company according to the payment rule
By transfer - you will receive an advance invoice in your email no later than the next working day, where you will find the account number, which you enter when making the payment.
Invoice - this payment option is available to partners who have a framework agreement with us.
If you want to use the last two payment methods, please call our manager and he will give you instructions on how to get an invoice with or without VAT.
The electronic devices we supply meet high quality standards, have a 24-month warranty, and meet all EU requirements.
In the event of a complaint, there is no charge for returning the product.
Three-phase network parameter analyzer - three-phase multifunction meter digital panel, current, voltage, frequency, and total power indicator, with two relay outputs and digital input, RS485 ModBus RTU - TPM-05 manufacturer TENSE (Turkey) panel meters.
Energy analyzers are designed for measuring and monitoring electrical values. Thanks to the communication function, energy measurements can be monitored and reported independently. Energy analyzers can perform analyses such as energy quality, efficiency, and calculating unit prices.
Main advantages:
- RS485 Modbus RTU (1200-115200bps)
- Three-phase voltage transformer and three-phase current transformer.
-
Displays harmonic voltages and currents up to the 55th harmonic
-
Displays active powers by phase (P)
-
Displays reactive powers by phase (Q, inductive and capacitive)
-
Displays apparent powers by phase (S)
-
Displays Cosφ values and power factor for each phase
-
Displays phase - neutral, phase - phase voltages (V) and currents (I) for each phase, frequency measurement
-
Displays total values of active energy import and export (ΣkWh)
-
Displays total inductive and capacitive reactive energy values (ΣkVArh)
-
Displays minimum and maximum values, max. demand
-
2 relay outputs, 1 digital input
-
Event logs (high/low voltage/current, voltage/current imbalance, THD-I, energy interruption)
-
Real date and time (RTC)
-
The menu is password protected.
This network analyzer is generally used with current transformers - 60/5 75/5 100/5 150/5 200/5 250/5 300/5 400/5 500/5 600/5 800/5 1000/5 1500/5 or equivalent. You can purchase such transformers from our online store, just click the link - Device transformers.
If you are going to connect the analyzer to ModBus, we will send you a request for the register table of ModBus addresses.